ANDERSON GAS SEPARATION / SCRUBBING EQUIPMENT SELECTION GUIDE

REMOVAL OF LIQUIDS/LIQUIDS-SOLIDS/SOLIDS FROM GAS/VAPOR STREAMS

Particle Type
Required Removal
Required Turndown at
Recommended Separator
Anderson Model Numbers
  Efficiency Rated Efficiency Type  
Liquids; Liquids&
99% of 10 Micron &
Up to 4:1
Solids Larger     TL, HSW, 530
Liquids; Solids; Both
100% of 8 Micron & Larger-Liquids 5:1
Multicyclone
AMC

100% of 5 Micron & Larger - Solids

(8-45 acfm/tube)

Liquids Only
100% of 8 Micron &
0-110% Rated Flow
  Larger      
Solids Only
100% of 3 Micron &
0-110% Rated Flow
ADGF
  Larger      
Solids, Liquids
100% of 3 Micron & Larger - Liquids/Solids
0-110% Rated Flow

99% of 0.5 - 3 Micron -Solids

Solids, Liquids
99.98% 0.3 Micron &
0-100% Rated Flow
  Larger