Contact Dwyer Sales Department: 1-201-419-6120  |  dwyer@nciweb.com


Dwyer Series DS - In-Line Flow Sensors

Use with the Dwyer Differential Pressure Gages or Transmitters

In-Line Flow Sensors are averaging Pitot tubes that provide accurate and convenient flow rate sensing for schedule 40 pipe. When purchased with a Dwyer® Capsuhelic® differential pressure gage of appropriate range, the result is a flow indicating system delivered off the shelf at an economical price.

Pitot tubes have been used in flow measurement for years. Conventional Pitot tubes sense velocity pressure at only one point in the flowing stream. Therefore, a series of measurements must be taken across the stream to obtain a meaningful average flow rate. The Dwyer® flow sensor eliminates the need for "traversing" the flowing stream because of its multiple sensing points and built-in averaging capability.

Dwyer® Series DS-300 flow sensors are designed to be inserted in the pipeline through a compression fitting. They are furnished with instrument shut-off valves on both pressure connections. Valves are fitted with 1/8" female NPT connections. Accessories include adapters with 1/4" SAE 45° flared ends compatible with hoses supplied with the Model A-471 Portable Capsuhelic® Gage Kit. Standard valves are rated at 200 psig (13.7 bar) and 200°F (93.3°C). Where valves are not required, they can be omitted at reduced cost. Series DS-300 flow sensors are available for pipe sizes from 1" to 10". If replacing a DS-200 flow sensor or using an A-160 threadolet with a DS-300, an optional 1/4" x 3/8" bushing, P/N A-161 is required.

DS-400 Averaging Flow Sensors are quality constructed from extra strong 3/4" dia. stainless steel to resist increased forces encountered at higher flow rates with both air and water. This extra strength also allows them to be made in longer insertion lengths up to 24 inches (61 cm). All models include convenient and quick-acting quarter-turn ball valves to isolate the sensor for zeroing. Process connections to the valve assembly are 1/8" female NPT. A pair of 1/8" NPT x 1/4" SAE 45° flared adapters are included, compatible with hoses used in the Model A-471 Portable Capsuhelic® Gage Kit. Supplied solid brass mounting adapter has a 3/4" dia. compression fitting to lock in required insertion length and a 3/4" male NPT thread for mounting in a threadolet (not included).

Model DS-300 Dimensions
Model DS-400 Dimensions
How To Order

Merely determine the pipe size into which the flow sensor will be mounted and designate the size as a suffix to Model DS-300. For example, a flow sensor to be mounted in a 2" pipe would be a Model No.DS-300-2".

For non-critical water and air flow monitoring applications, the chart below can be utilized for ordering a stock Capsuhelic® differential pressure gage for use with the DS-300 flow sensor. Simply locate the maximum flow rate for the media being measured under the appropriate pipe size and read the Capsuhelic® gage range in inches of water column to the left. The DS-300 sensor is supplied with installation and operating instructions, Bulletin F-50. It also includes complete flow conversion information for the three media conditions shown in the chart below. This information enables the user to create a complete differential pressure to flow rate conversion table for the sensor and differential pressure gage employed. Both the Dwyer® Capsuhelic® gage and flow sensor feature excellent repeatability so, once the desired flow rate is determined, deviation from that flow in quantitative measure can be easily determined. You may wish to order the adjustable signal flag option for the Capsuhelic® gage to provide an easily identified reference point for the proper flow.

Capsuhelic® gages with special ranges and/or direct reading scales in appropriate flow units are available on special order for more critical applications. Customer supplied data for the full scale flow (quantity and units) is required along with the differential pressure reading at that full flow figure. Prior to ordering a special Capsuhelic® differential pressure gage for flow read-out, we recommend you request Bulletin F-50 to obtain complete data on converting flow rates of various media to the sensor differential pressure output. With this bulletin and after making a few simple calculations, the exact range gage required can easily be determined.

GAGE RANGE (IN. W.C.) MEDIA @ 70°F FULL RANGE FLOWS BY PIPE SIZE (APPROXIMATE)
1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" 6" 8" 10"
2 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
4.8
19.0
50.0
8.3
33.0
90.5
11.5
42.0
120.0
20.5
65.0
210.0
30
113
325
49
183
510
86
330
920
205
760
2050
350
1340
3600
560
2130
6000
5 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
7.7
30.0
83.0
14.0
51.0
142.0
18.0
66.0
190.0
34.0
118.0
340.0
47
178
610
78
289
820
138
510
1600
320
1200
3300
560
2150
5700
890
3400
10000
10 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
11.0
41.0
120.0
19.0
72.0
205.0
25.5
93.0
275.0
45.5
163.0
470.0
67
250
740
110
410
1100
195
725
2000
450
1690
4600
800
3040
8100
1260
4860
15000
25 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
18.0
63.0
185.0
32.0
112.0
325.0
40.5
155.0
430.0
72.0
255.0
760.0
108
390
1200
173
640
1800
310
1130
3300
720
2630
7200
1250
4860
13000
2000
7700
22000
50 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
25.0
90.0
260.0
44.0
161.0
460.0
57.5
205.0
620.0
100.0
360.0
1050.0
152
560
1700
247
900
2600
435
1600
4600
1000
3700
10000
1800
6400
18500
 
100 Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
36.5
135.0
370.0
62.0
230.0
660.0
82.0
300.0
870.0
142.0
505.0
1500.0
220
800
2300
350
1290
3600
620
2290
6500
1500
5000
15000
   
Popular DS-300 Models:
Model Number Pipe Size
 DS-300-1 1"
 DS-300-1-1/4 1 1/4"
 DS-300-1-1/2 1 1/2"
 DS-300-2 2"
 DS-300-2-1/2 2 1/2"
 DS-300-3 3"
 DS-300-4 4"
 DS-300-6 6"
 DS-300-8 8"
 DS-300-10 10"
 
Popular DS-400 Models:
Model Number Pipe Size
 DS-400-6 6"
 DS-400-8 8"
 DS-400-10 10"
 DS-400-12 12"
 DS-400-14 14"
 DS-400-16 16"
 DS-400-18 18"
 DS-400-20 20"
 DS-400-24 24"
Previous Page