SLEX-100 / REX-100 HI-LED Explosion Proof Lights — UL-844 Listed — Northeast Controls Inc.
Explosion Proof — UL-844 & C-UL/CSA C22.2 Listed

SLEX-100 & REX-100 Series

Halogen & HI-LED Explosion-Proof Lighting for Single-Port Sightglass Viewing

SLEX-100 REX-100 explosion proof sightglass light for hazardous locations

The SLEX/REX-100 series are compact, explosion-proof sight lights that deliver bright, glare-free illumination into vessels, tanks, hoppers, silos, mixers, and pipelines through a single sight port. UL-844 and C-UL/CSA C22.2 No. 137 listed for hazardous (classified) locations, these fixtures mount completely externally to the sightglass flange — entirely outside vessel pressure. Available in halogen and High-Intensity LED (HI-LED) versions, with a sanitary clamp model for food, beverage, and pharmaceutical applications.

The fixture can also serve as an illumination port paired with a separate viewing sightglass — for example, for TV or video camera monitoring applications.

Halogen & LED Model Overview

SLEX-100

Standard Model

No internal reflector. Compact explosion-proof light for single-port sightglass viewing in hazardous locations. Available in halogen or HI-LED.

REX-100

Reflector Model

Equipped with a highly polished internal reflector that increases illumination intensity over the standard SLEX-100. Available in halogen or HI-LED.

SLEX-100 HI-LED

Standard + High-Intensity LED

Same 100W equivalent output as halogen with dramatically longer lamp life (40,000–50,000 hours). Cool operation, vibration immune.

REX-100 HI-LED

Reflector + High-Intensity LED

Polished reflector combined with HI-LED technology for maximum illumination intensity and long-life, low-maintenance operation.

Electrical Specifications

Voltage120 VAC standard (220/230 VAC also available)
Maximum Power100 watts (UL & C-UL listed maximum)
Approximate Output~1,800 lumens
Conduit Entries½" FNPT (3 places)
Supply Wire Rating150°C minimum required

Hazardous Location Ratings

Identical ratings apply to both halogen and HI-LED versions.

ModelReflectorWattsClassDivGroupTemp Code / Max Temp
REX-100 HalogenYes100I1, 2C, DT4A / 120°C (248°F)
SLEX-100 | SLEX-100 Hi-LEDNo100I1, 2C, DT4A / 120°C (248°F)
SLEX-100 | SLEX-100 Hi-LEDNo100II1E, F, GT3C / 160°C (320°F)

* Operating temperatures exceed safe temperatures for some Group C materials. Install only as intended. Always verify current ratings with factory.

Temperature Code Reference

CodeMax °CMax °F
T1450°C842°F
T2300°C572°F
T2A280°C536°F
T2B260°C500°F
T2C230°C446°F
T2D215°C419°F
T3200°C392°F
T3A180°C356°F
T3B165°C329°F
T3C160°C320°F
T4135°C275°F
T4A120°C248°F
T5100°C212°F
T685°C185°F

Highlighted codes (T4A, T3C) are the ratings applicable to the SLEX-100 HL. Maximum operating temperature data should be used by the plant safety engineer to determine suitability for their specific hazardous location.

Construction & Design Features

  • Relamp without removing the fixture from the sight port or disturbing any wiring
  • Separate, individually explosion-proof lamp and wiring compartments
  • Heavy-wall copper-free aluminum alloy castings (No. 356T6) — corrosion resistant
  • Borosilicate glass lens with precision-machined seal
  • Supplied with slotted mounting brackets for easy installation on new or existing sightglasses (3-1/4", 4", or larger circular flanges)
  • ½" FNPT conduit entries (3 places)
  • Fixtures mount completely externally to the sightglass flange — outside vessel pressure

Halogen Models — Ordering Reference

Halogen

The SLEX-100 and REX-100 halogen series use a high-intensity halogen lamp to provide bright, glare-free illumination through a single sight port. The REX-100 adds a highly polished internal reflector for increased illumination intensity over the standard SLEX-100. Both series are UL-844 and C-UL/CSA C22.2 No. 137 listed for Class I, Division 1 hazardous locations. Available in 50 W and 100 W versions at 120, 230, or 240 VAC. The halogen lamp is also available as a retrofit into existing SLEX-100 housings, and the fixture can be relamped without removing it from the sight port or disturbing any wiring.

Item #LampMax PowerClassDivGroupVoltage / Reflector
REX-100-00Halogen100 WI1C, D120 V · Reflector: Yes
REX-100-01Halogen100 WI1C, D240 V · Reflector: Yes
REX-100-02Halogen50 WI1C, D240 V · Reflector: Yes
REX-100-02-1Halogen50 WI1C, D230 V · Reflector: Yes
SLEX-100-00Halogen100 WIII1, 2C, D, E, F, G120 V · Reflector: No
SLEX-100-01Halogen100 WIII1, 2C, D, E, F, G240 V · Reflector: No
SLEX-100-02Halogen100 WIII1, 2C, D, E, F, G120 V · Reflector: No
SLEX-100-02-1Halogen50 WIII1, 2C, D, E, F, G230 V · Reflector: No

REX-100 series includes a polished internal reflector for higher illumination intensity. SLEX-100 series is the standard (no reflector) model. Contact Northeast Controls for 220 VAC or other voltage configurations.

SLEX-100 Hi-LED engine assembly
SLEX-100 Hi-LED complete unit with bracket

HI-LED Models — Ordering Reference

Recommended

The SLEX-HI-LED and REX-HI-LED series use High-Intensity LED (HI-LED) light engine technology to deliver bright, glare-free illumination through a single sight port — without the heat, short lamp life, or high energy draw of halogen. At only 8 watts actual draw (100W equivalent output), these fixtures provide 22% more light intensity than a 100W halogen bulb while consuming 93% less energy. UL-844 and C-UL/CSA C22.2 No. 137 listed. Available in 120 V and 240 V; the REX-HI-LED adds a polished internal reflector for increased intensity.

Item #LampPowerClassDivGroupVoltage / Reflector
REX-HI-LED-00HI-LED8 W (100 W equiv.)I1C, D120 V · Reflector: No
REX-HI-LED-01HI-LED8 W (100 W equiv.)I1C, D240 V · Reflector: No
SLEX-HI-LED-00In StockHI-LED8 W (100 W equiv.)III1, 2C, D, E, F, G120 V · Reflector: No
SLEX-HI-LED-01HI-LED8 W (100 W equiv.)III1, 2C, D, E, F, G240 V · Reflector: No

All HI-LED models: 8W actual / 100W equivalent. REX-HI-LED includes polished internal reflector. SLEX-HI-LED is the standard (no reflector) model. Contact Northeast Controls for other voltage configurations or SVTC sanitary clamp HI-LED models.

Why Upgrade to HI-LED?

35,000-Hour Lamp Life

vs. 1,000–2,000 hours for halogen — dramatically fewer replacements, lower labor costs, and less downtime. Lasts 98% longer than a standard 100W halogen bulb.

No Excessive Heat

No heat transmission into the sightglass or vessel. Far less heat generation than a 100W halogen bulb. Housing stays cool — continuous operation without overheating.

Robust Technology

Vibration, heat, dust, and surface-oil resistant. No filament means shock and vibration will not affect lamp life — ideal for pumps, mixers, and mobile equipment.

22% More Light Than 100W Halogen

Twice the light at 1/3 the wattage of other LED fixtures. ~1,800 lumens equivalent output with custom optics for uniform, bright white light.

Uniform White Light — No Hot Spots

Custom optics provide bright, white, high-intensity, uniform illumination with no hot spots or yellow tint. Ideal for video camera monitoring systems.

93% Less Energy

Only 8 watts actual draw vs. 100 watts for halogen. Energy savings alone can offset the cost of upgrading in many applications.

LM80 Tested / Energy Star

LED array LM80 tested to Energy Star standards. Continuous operation capability without burning out the lamp or overheating electronics.

Maintenance-Free Operation

Extended lamp life reduces the inconvenience of replacing burned-out lamps, especially in difficult-to-access or hazardous locations.

Sanitary Clamp Model

SLEX/SVTC & REX/SVTC — Sanitary HI-LED Light Glasses

Combination Explosion-Proof HI-LED Light & Integral Sanitary Clamp Sightglass Assembly

The SLEX/SVTC and REX/SVTC series integrate a Series SVTC sanitary clamp-type sightglass directly into the SLEX/REX explosion-proof lighting fixture — the lens is an integral part of the unit, not a loose component. This allows users to illuminate the contents of a pressurized vessel or pipeline with HI-LED or 100W halogen intensity on existing standard sanitary clamp ferrules. Anodized aluminum parts provide greater cleanliness and aesthetic appeal, making the unit highly popular for pharmaceutical applications. All wetted parts are machined T316 stainless steel (optional materials available), PTFE, and glass.

Key Specifications

Clamp Sizes3" or 4" sanitary clamp (standard)
Wetted MaterialsMachined T316 stainless steel, PTFE, borosilicate glass
HousingAnodized aluminum — corrosion resistant, cleanroom-friendly
Pressure Rating150 PSIG / full vacuum (standard); higher ratings available
Temperature Limit500°F standard; higher temperature ratings available
Light SourceHI-LED (8W / 100W equiv.) or 100W Halogen
ListingsUL-844 & C-UL/CSA C22.2 No. 137 — explosion-proof, hazardous locations
ApplicationsPharmaceutical, food & beverage, biotech, sanitary process

SVTC HI-LED Models — Ordering Reference

Item #ClampPowerClassDivGroupVoltageReflector
REX-HI-LED-00/3"SVTC3"8W / 100W eq.I1C, D120 VYes
REX-HI-LED-00/4"SVTC4"8W / 100W eq.I1C, D120 VYes
REX-HI-LED-01/3"SVTC3"8W / 100W eq.I1C, D240 VYes
REX-HI-LED-01/4"SVTC4"8W / 100W eq.I1C, D240 VYes
SLEX-HI-LED-00/3"SVTC3"8W / 100W eq.I–III1, 2C, D, E, F, G120 VNo
SLEX-HI-LED-00/4"SVTC4"8W / 100W eq.III1, 2C, D, E, F, G120 VNo
SLEX-HI-LED-01/3"SVTC3"8W / 100W eq.III1, 2C, D, E, F, G240 VNo
SLEX-HI-LED-01/4"SVTC4"8W / 100W eq.III1, 2C, D, E, F, G240 VNo

REX/SVTC includes polished internal reflector for higher illumination intensity. SLEX/SVTC is the standard (no reflector) model. Halogen SVTC models also available — contact Northeast Controls for configurations not listed.

Dimensions (Typical — SLEX/REX-100)

Overall Width (across brackets)10 7/8" (276 mm)
Body Diameter4½" (114 mm)
Height (body)4 1/8" to 4 13/16" depending on view
Conduit Hubs½" FNPT (3 places)

For complete dimensional drawings, IOM manual, or certified prints, contact Northeast Controls. Refer to factory drawing SLEX-100-SVTC-DWG for SVTC clamp details.

Installation Highlights

Verify Classification

Confirm fixture rating matches the area classification before installation.

De-Energize Circuit

De-energize circuit before installation. Operate via customer-supplied hazardous-location switch.

Secure Mounting

Mount fixture centered and securely to sightglass using supplied brackets. Ensure rigid, vibration-free installation.

Wiring Requirements

Use 150°C-rated supply wire. Ground through conduit. Ensure enclosure is fully closed and sealed before energizing.

Listings & Certifications

UL-844

Electric lighting fixtures for hazardous (classified) locations

C-UL/CSA C22.2 No. 137

Canadian listing for hazardous location lighting fixtures

Made in USA

UL & cUL listed explosion-proof lighting for hazardous locations since 1969

SLEX-100 / REX-100 — Pricing & Availability

1-201-419-6111 · [email protected]

Request Pricing