Universal Silencer Series BRH  Filter

For use on Centrifugal Compressors, Blowers, Engines, Gas Turbines. (For reciprocating compressors, contact factory for recommendations.)
Universal BFH Series Air Filter is a compact, inexpensive unit designed to employ standard panel filters which are available in a variety of types and efficiencies as shown elsewhere in this catalog. In cases where noise is a consideration, the BFH is commonly used in series with a separate inlet silencer. The filter holding frames in the housing accommodate conventional 2" deep panel filter elements - single stage only. These units are fabricated of steel sheet and plate, welded throughout to provide a rugged, long-lasting trouble-free air filtering component. The filter is equipped with removable weather-hoods and for convenience of mounting, the bottom plate contains an opening and bolting pattern which match 125/150# ANSI flange specifications. Inside and outside surfaces are primed with a rust inhibitor and may be finish painted in the field if desirable.
 
    Nominal Capacity              
Model Configuration C . F. M.(1.) A B C D E Weight (2.) No. 8 Size of Filter Openings
BFH-4-50 Fig. A 450 4 12-1/4 12-1/4 13 21-1/2 30 1-12x12x2
BFH-5-50 Fig. B 700 5 12-1/4 12-1/4 16 23-1/2 40 2-12x1 2x2
BFH-6-10 Fig. B 1000 6 20-1/4 16-1/4 17 28-1/2 50 2-16x20x2
BFH-8-30 Fig. B 1750 8 20-1/4 20-1/4 20 31-1/2 70 2-20x20x2
BFH-10-40 Fig. B 2750 10 25-1/4 20-1/4 23 37 80 2-20x25x2
BFH-10-30 Fig. C 2750 10 20-1/4 26-1/4 26-1/4 37-3/4 100 4-20x20x2
BFH-12-30 Fig. C 4000 12 20-1/4 27-1/4 27-1/4 38-3/4 10 4-20x20x2
BFH-12-40 Fig. C 5000 12 25-1/4 27-1/4 27-1/4 41-1/4 110 4-20x25x2
BFH-14-40 Fig. C 5000 14 25-1/4 27-1/4 27-1/4 41-1/4 110 4-20x25x2
Dimensions In Inches, Weights In Lbs.
(1.) Nominal capacity is based on exit velocity of approximately 5000 ft. /min. (Capacity of filter elements may be greater. but this is unrelated to actual unit capacity, which is primarily a function of outlet size.) For specific sizing and pressure drop data.
(2.) Weights do not include filter elements.
 