Universal Silencer Filter Elements — W-2, DD-2, P-II, Cartridge, Gas Turbine — Northeast Controls Inc.

Dürr Universal Silencers — Air Filtration

Filter Elements

W-2 · DD-2 · P-II Panel Elements · Cartridge Elements · Gas Turbine Elements

Panel Elements

W-2DD-2P-II

Cartridge Elements

CS/CCS/CF/CCF

Gas Turbine Elements

Pulse-JetStaticHigh-Efficiency

Dürr Universal Silencers supplies replacement filter elements for all of their panel filter, cartridge filter, and gas turbine inlet filter housing product lines. Elements are available in pleated cellulose, felted polyester, galvanized wire mesh, and high-efficiency synthetic and glass fiber media. Keeping replacement elements in stock minimizes downtime during scheduled filter changeouts.

Panel Filter Elements

FH · FSH · BFH · FRH Series Housings

Standard 20" × 25" × 2" panel filter elements for use in FH, FSH, BFH, and FRH series filter housings. Three media types are available — W-2 pleated cellulose, DD-2 felted polyester, and P-II galvanized wire mesh — to suit different service environments and filtration requirements.

W-2Pleated Cellulose Panel ElementPleated cellulose
Efficiency: Standard efficiencyApplication: General-purpose inlet air filtration for blowers and compressors
Pleated cellulose media — high surface area
Standard efficiency for general industrial service
Fits FH, FSH, BFH, and FRH series housings
Standard 20" × 25" × 2" panel size
Economical replacement element
Dry media — no oil required

Most common replacement element for blower and compressor inlet filter housings.

DD-2Felted Polyester Panel ElementFelted polyester
Efficiency: Higher efficiency than W-2Application: Blower and compressor inlet filtration in dusty or humid environments
Felted polyester media — moisture resistant
Higher efficiency than pleated cellulose W-2
Suitable for humid and damp environments
Fits FH, FSH, BFH, and FRH series housings
Standard 20" × 25" × 2" panel size
Longer service life in dusty conditions

Preferred over W-2 in humid climates or where moisture ingestion is a concern.

P-IIGalvanized Wire Mesh Panel ElementGalvanized wire mesh (washable)
Efficiency: Pre-filter / coarse filtrationApplication: Pre-filtration stage; washable and reusable
Galvanized wire mesh — washable and reusable
Coarse pre-filter for large particle removal
Extends service life of downstream fine filter elements
Fits FH, FSH, BFH, and FRH series housings
Standard 20" × 25" × 2" panel size
Reduces overall filter replacement cost

Used as a pre-filter upstream of W-2 or DD-2 elements to extend their service life.

Panel Filter Element Part Numbers

Standard panel filter elements, wire mesh, polyester felt, pleated paper, aluminum frame, stainless steel, and accessory items.

ModelPart No.SizeDescriptionWgt.
P-881-039820 x 25 x 8Absolute panel filter - 1st stage; glass29
P-8 pad81-040020 x 25 x 2Absolute panel filter - pre-filter pad1
P-12F81-042920 x 25 x 12Absolute panel filter - 2nd stage; glass44
W-2-5081-041012 x 12 x 2Panel element; galvanized wire mesh4
W-2-1081-016216 x 20 x 2Panel element; galvanized wire mesh8
W-2-2081-016316 x 25 x 2Panel element; galvanized wire mesh10
W-2-3081-016420 x 20 x 2Panel element; galvanized wire mesh10
W-2-4081-016520 x 25 x 2Panel element; galvanized wire mesh11
DD-2-5081-041112 x 12 x 2Panel element; polyester felt4
DD-2-1081-017016 x 20 x 2Panel element; polyester felt7
DD-2-2081-017116 x 25 x 2Panel element; polyester felt9
DD-2-3081-017220 x 20 x 2Panel element; polyester felt8
DD-2-4081-017320 x 25 x 2Panel element; polyester felt9
P-1181-032620 x 25 x 2Panel element; pleated paper8
P-581-03175 dia x 6.7 longCartridge element; pleated paper (48/case)
P-5E81-04215 dia x 6.7 longCartridge element; epoxy coated paper (48/case)
WAA2-4081-043520 x 25 x 2Aluminum frame and media
DDAA2-3081-048620 x 20 x 2Aluminum frame and media
DDAA2-4081-048320 x 25 x 2Aluminum frame and media
WSS2-4081-046420 x 25 x 2304SS frame and 316SS screen cloth
WSS2-4581-047824 x 24 x 2304SS frame and 316SS screen cloth
DDSS2-1081-104516 x 20 x 2304SS frame and 316SS screen cloth
DDSS2-2081-104616 x 25 x 2304SS frame and 316SS screen cloth
DDSS2-3081-104720 x 20 x 2304SS frame and 316SS screen cloth
DDSS2-4081-048120 x 25 x 2304SS frame and 316SS screen cloth
DDGS2-4081-044120 x 25 x 2Galvanized frame, 304SS expanded metal, 316SS screen cloth
P-5 adapter87-0266P-5 cartridge filter adapter1
P-681-149720 x 25 x 6Panel element; pleated paper; hospital grade25
GP-2-4081-154320 x 25 x 2Pre-filter pad with frame4
81-032313 oz.Oil free adhesive (6/case)6
81-1234Filter restriction gauge1
81-1026Magnehelic gauge1

Cartridge Filter Elements

CS · CCS · CF · CCF Series Housings

Round pleated cartridge filter elements for use in CS, CCS, CF, and CCF series cartridge filter-silencer housings. Available in ½" through 16" inlet sizes to match the housing connection size. Flow range 15 to 7,700 CFM.

Standard Cartridge ElementRound Cartridge Filter Element
Housing: CS, CCS, CF, CCF seriesSizes: ½" to 16" inlet connectionFlow: 15 to 7,700 CFM
Pleated filter media — high surface area
Round cartridge form factor
Fits CS, CCS, CF, and CCF series housings
Available in ½" through 16" inlet sizes
Flow range 15 to 7,700 CFM
Dry media construction

Standard replacement element for all CS, CCS, CF, and CCF series cartridge filter-silencers.

Cartridge Element Selection by Pipe Size

Select the correct element part number based on nominal pipe size and media type. Part numbers marked (old) are superseded — use the current number when available.

P (Nom.)PaperFeltWire Mesh
1/281-047081-120281-1035
3/481-047081-120281-1035
181-047081-120281-1035
1-1/481-047181-120381-1036
1-1/281-047181-120381-1036
281-047181-120381-1036
2-1/281-1063, 81-0472 (old)81-1205, 81-1204 (old)81-1038, 81-1037 (old)
381-1063, 81-0472 (old)81-1205, 81-1204 (old)81-1038, 81-1037 (old)
3-1/281-106381-120581-1038
481-106381-120581-1038
581-1063, 81-0474 (old)81-1205, 81-1206 (old)81-1038, 81-1039 (old)
681-047581-120781-1040
881-0475 (2)81-1207 (2)81-1040 (2), 81-1199 (old)
1081-116381-120981-1200
1281-116381-120981-1200
1481-116481-121081-1201
1681-116481-121081-1201

Gas Turbine Filter Elements

Pulse-Jet · Static · Two-Stage Housings

Replacement filter elements for gas turbine inlet filter housings — pulse-jet self-cleaning cartridges, static panel and bag elements, and high-efficiency final-stage elements. Available for Solar, GE, Siemens, Westinghouse, ABB, and other major turbine OEM housings. Custom sizes available for retrofit applications.

Pulse-Jet CartridgePulse-Jet Self-Cleaning Cartridge ElementPulse-jet self-cleaning filter housings
Designed for pulse-jet reverse-air cleaning systems
High-efficiency pleated media
Withstands repeated pulse-cleaning cycles
Extended service life vs. static elements
Available in standard and custom sizes
MERV-rated media options available

Used in pulse-jet self-cleaning gas turbine inlet filter housings. Cleaned in-place by reverse air pulse — no shutdown required for cleaning.

Static Panel / BagStatic Panel and Bag Filter ElementsStatic and two-stage gas turbine filter housings
Pre-filter panels (coarse) + final bag or cartridge (fine)
Two-stage filtration for high-efficiency performance
Synthetic and glass fiber media options
MERV 8 through MERV 16 efficiency ratings
Custom sizes for OEM and retrofit housings
Available for Solar, GE, Siemens, Westinghouse, ABB turbines

Used in static and two-stage gas turbine inlet filter housings. Pre-filter panels are replaced more frequently; final elements are replaced on a longer interval.

High-Efficiency Final ElementHigh-Efficiency Final Filter ElementTwo-stage and integrated silencer-filter housings
High-efficiency final stage element
Glass fiber or synthetic media
MERV 14 to MERV 16 efficiency
Protects turbine compressor blades from fouling
Reduces turbine maintenance intervals
Custom sizes for all major turbine OEMs

Final-stage element in two-stage gas turbine filtration systems. Critical for protecting turbine compressor blades from salt, dust, and particulate fouling.

Filter Media Comparison

Media / ModelEfficiencyMoistureWashableBest For
Pleated Cellulose (W-2)StandardNot recommendedNoGeneral industrial blower/compressor inlet
Felted Polyester (DD-2)HigherSuitableNoHumid environments, dusty conditions
Galvanized Wire Mesh (P-II)Coarse pre-filterSuitableYesPre-filter stage; reusable
Pleated CartridgeStandard–HighDry serviceNoCS/CCS/CF/CCF cartridge housings
Pulse-Jet CartridgeHighDry servicePulse-cleanedGas turbine pulse-jet housings
Static Panel/BagMERV 8–16Dry serviceNoGas turbine static/two-stage housings
High-Efficiency FinalMERV 14–16Dry serviceNoGas turbine final-stage protection

2026 Standard Products — Filter Silencer Catalog Data

Dürr Universal Silencers Rev. 01 / 2026. Weights are approximate. Filter elements are non-returnable. Minimum order $200. Shipping point: Laredo, TX.

CCF Series — Cartridge Filter-Silencers (with Paper Element)

Intake filter-silencer with paper element. Threaded (TT) or flanged (AA) connections.

SizeP/NMM#DescriptionWeight (lbs)
1.5"34-L15-TTP1000001847CCF-1 1/2 FILTER W/PAPER9
2"34-L02-TTP1000001367CCF-2 FILTER W/PAPER7
2.5"34-L25-TTP1000001417CCF-2 1/2 INTAKE FILTER W/PAPER11
3"34-L03-TTP1000000907CCF-3 INTAKE FILTER W/PAPER10
3.5"34-L35-TTP1000001753CCF-3 1/2 FILTER W/PAPER13
4" (THD)34-L04-TTP1000000912CCF-4 INTAKE FILTER THD W/PAPER12
4" (FLG)34-L04-AAP1000000910CCF-4 INTAKE FILTER FLG W/PAPER14
5" (THD)34-L05-TTP1000000909CCF-5T INTAKE FILTER THD W/PAPER12
5" (FLG)34-L05-AAP1000001002CCF-5 INTAKE FILTER FLG W/PAPER16
6"34-L06-AAP1000001399CCF-6 INTAKE FILTER W/PAPER31
8"34-L08-AAP1000001335CCF-8 INTAKE FILTER W/PAPER43
10"34-L10-AAP1000001400CCF-10 INTAKE FILTER W/PAPER52
12"34-L12-AAP1000001336CCF-12 INTAKE FILTER W/PAPER64
14"34-L14-AAP1000001401CCF-14 INTAKE FILTER W/PAPER97

CCS Series — Cartridge Filter-Silencers (with Paper Element)

Intake filter-silencer with paper element. Threaded (TTP) or flanged (AAP) connections. Larger body than CCF for higher flow capacity.

SizeP/NMM#DescriptionWeight (lbs)
1.5"34K15TTP1000001749CCS-1 1/2 FILTER W/PAPER10
2"34K02TTP1000001396CCS-2 INTAKE FILTER W/PAPER8
2.5"34K25TTP1000001468CCS-2 1/2 FILTER W/PAPER19
3"34K03TTP1000001145CCS-3 INTAKE FILTER W/PAPER18
4" (THD)34K04TTP1000001151CCS-4T INTAKE FILTER THD W/PAPER19
4" (FLG)34K04AAP1000001148CCS-4 INTAKE FILTER FLG W/PAPER21
5" (THD)34K05TTP1000001157CCS 5T INTAKE FILTER THD W/PAPER19
5" (FLG)34K05AAP1000001154CCS-5 INTAKE FILTER FLG W/PAPER23
6"34K06AAP1000001397CCS-6 INTAKE FILTER W/PAPER43
8"34K08AAP1000001334CCS-8 INTAKE FILTER W/PAPER56
10"34K10AAP1000001398CCS-10 INTAKE FILTER W/PAPER83
12"34K12AAP1000001332CCS-12 INTAKE FILTER W/PAPER91
14"34K14AAP1000001394CCS-14 INTAKE FILTER W/PAPER143
16"34K16AAP1000001333CCS-16 INTAKE FILTER W/PAPER145

Replacement & Maintenance Guidance

Replacement intervalBased on pressure drop across element — replace when ΔP reaches manufacturer limit
Pressure drop indicatorMagnehelic gauge or differential pressure switch recommended on all housings
W-2 / DD-2 service lifeTypically 6–12 months in normal industrial service; shorter in high-dust environments
P-II mesh elementWash and re-oil per manufacturer instructions; inspect for damage before reinstalling
Cartridge elementsReplace when ΔP limit reached; do not attempt to clean pleated cartridge elements
Gas turbine elementsPulse-jet elements cleaned in-place; static elements replaced on scheduled interval or ΔP
Stocking recommendationKeep 1–2 sets of replacement elements on hand to minimize downtime during changeout

Ordering Replacement Elements

To order replacement filter elements, provide the housing model number (found on the housing nameplate), the element type (W-2, DD-2, P-II, or cartridge), and the quantity required. For gas turbine filter elements, provide the turbine OEM and model number. Contact Northeast Controls Inc. for pricing and availability.

Order Replacement Filter Elements

Northeast Controls Inc. supplies replacement filter elements for all Dürr Universal Silencers filter housing product lines. Contact us with your housing model number and element type for pricing and availability.