Front Panel Selectable Inputs: Thermocouple, RTD, DC voltage or DC current.
Supply Pressure: Minimum: EP1000: 18 psig (1.24 bar); EP1011: 33 psig (2.28 bar); Maximum: 100 psig (6.89 bar).
Output: EP1000: 3 to 15 psig (0.21 to 1.03 bar); EP1011: 6 to 30 psig (0.41 to 2.07 bar).
Accuracy: ±1.0% of span.
Linearity: ±0.75% of span.
Hysteresis: ±1.0% of span.
Repeatability: ±0.5% of span.
Power Requirements: 100 to 240 VAC, 50/60 Hz.
Temperature Limits: 32 to 122°F (0 to 50°C).
Pressure Connections: 1/4" female NPT.
Air Consumption: 0.03 scfm (.05 m³/h) typical.
Output Capacity: 4.5 scfm (7.6 m³/h) at 25 psig (1.72 bar) supply; 12 scfm (20 m³/h) at 100 psig (6.89 bar) supply.
Enclosure: NEMA 4X.
Weight: 8 lb 1 oz (3.67 kg).
|