Contact Our Magnesonics Sales Team: 1+201-419-6111 or sales@nciweb.com


 

MAGNE-SONICS 600 SERIES Non-Contact Ultrasonic 2 or 3 V1ire Transmitter

The model 602 and 60' are integral non-contact ultrasonic level transmitters providing process measurement of linear level changes utilizing proven time of flight technology. These units feature a low compact profile design comprised of an integral control unit transducer. The electronics are housed in a NEMA 4X enclosure and include as standard a 4 digit LCD and a 4-20 mA output.

The function of the control electronics is to precisely measure the time period between the transmitted echo pulse and the reflected echo pulse to determine the process level. A series of digital software algorithms fine tune the returned echo to ensure the correct return echo pulse is monitored.

The 602 and 603 transmitters are easily mounted above the process using the 2" NPT process connection. The transducer construction is UPVC or PTFE as specified.

Setup is simplified by the menu driven software and five keypads used for configuration of the required span, bottom reference distance, and the adjustable dampening feature. Loss of echo alarm is field selectable - driving 4mA. 20mA. or hold last value.

  • Non-Contact Ultrasonic
  • 4 Digit Alpha-Numeric LCD
  • Front Panel Keypad Entry
  • Menu Driven Configuration
  • Low Installation Cost
 
SPECIFICATIONS:
  • Range ............................... Model 602: 1.0 - 16.0 ft.
  • Range ............................... Model 603: 1.0 - 16.0 ft
  • Temperature Range .......... -35° to 150°F, -30° to 65°C
  • Fail Safe ........................... High/Low/Hold
  • Power Requirements ........Model 602 ................ 20 - 30 VDC, 2-wire
  • Power Requirements ........ Model 603 .......... 20 - 30 VDC. 3 or 4 wire
  • Output .............................. 4 - 20 mA DC 750 ohms max.
  • Accuracy .......................... ± 1.00% of span
  • Enclosure ......................... NEMA 4X
  • Beam Angle ..................... ± 6° @ -3db
  • Display ............................. 4 Digit LCD
  • Mounting ......................... 2" NPT
  • Net Weight ....................... 2.2 lbs. (1 kg)
 
DIMENSIONAL INFORMATION:
MODEL SELECTION GUIDE:
Non-Contact Ultrasonic Level Switch
Code --Control Unit
602 --4-20 mA Linear Level Switch, 2-wire 24 VDC Powered, Range 16.0 FT. 2" NPT Mount
603 --4-20 mA Linear Level Switch, 3-wire 24 VDC Powered, Range 16.0 FT. 2" NPT Mount
  Code -- Transducer Face
  P    UPVC
  T    PTFE
603 P     Typical Model Number
 
Previous Page